Section 4: operation, 01 front panel, Section 4 – Tweco VA 4000 Ultra-Feed User Manual

Page 29: Operation -1, 01 front panel -1, Ultrafeed va 4000

Advertising
background image

ULTRAFEED VA 4000

September 18, 2012

4-1

1

3

7

8

9

10

11

4

Art # A-06982

2

5

6

12

7. ARC VOLTAGE CONTROL: This knob controls arc

voltage or pulse frequency from the power source.
The arc voltage (or pulse reference) control can be
adjusted during setup or actual welding.

8. FUNCTION TIMERS: These knobs provide timed

control over preflow/postflow gas, wire burnback
distance and spot weld time.

9. 2 STEP / 4 STEP SWITCH: This switch selects 2 Step

or 4 Step mode of operation.

10.GAS PURGE SWITCH: This switch will purge shielding

gas when pressed.

11.INCH SWITCH: This switch will feed wire at the INCH

speed (default of set speed). The feeder does not
activate the contactor on the power source. Thus,
the wire will be cold as long as the power source
outputs are controlled by the contactor

.

SECTION 4:

OPERATION

4.01 Front Panel

1. GUN SWITCH RECEPTACLE: The gun switch receptacle

accepts the welding gun control wires. The gun switch
receptacle is where a gun switch closure is inputted to
the wire feeder.

2. FAULT INDICATOR: This LED indicates a fault condition

exists. If it is flashing, a ground fault has occurred. If
it is on continuously, the motor protection circuit has
activated.

3. WIRE FEED SPEED (WFS) CONTROL:

This knob controls wire feed speed. The wire feed
speed control knob can be adjusted during setup or
actual welding.

4. WFS/AMP METER: This meter displays the wire feed

speed or amperage.

5. WIRE SPEED FORCE METER

6. VOLT METER: Displays possible restriction in liner or

tips.

Figure 4-1: Front Panel Controls and Connections

Advertising