Ultrafeed va 4000s – Tweco VA 4000S Ultra-Feed User Manual
Page 29

ULTRAFEED VA 4000S
Manual No. 0-5135
4-3
OPERATION
12.32' CONTROL CABLE SOCKET: The 32' control cable connects to the VA 4000 S controller at the upper 19-pin
amphenol connector socket (of which 14 pins are used). It contains the signals required to allow the welding
power source, controller and the wire feeder to work together as a system. Refer to figure 4-3 and 4-4
WARNING
The protective earth ground (pin G) of the control cable is established only when the power source is
properly grounded. See the power source owner’s manual for proper grounding methods.
PIN LETTER
DESCRIPTION
WIRE COLOR
WIRE NUMBER
A
Motor Plus
RED
17
B
Motor Negative
BLACK
16
C
Gas Valve
BLUE
14
D
Gas Valve
WHITE
15
E
Board Pin 4
BLACK
N/A
F
Dual Schedule Receptacle-not used
N/A
N/A
G
Inch/Purge Common
RED
11
H
Purge
BROWN
10
J
Inch
YELLOW
9
K
Gun Switch
ORANGE
7
L
NOT USED
N/A
N/A
M
Board Pin 3
RED
N/A
N
Board Pin 2
YELLOW
N/A
P
Board Pin 1
WHITE
N/A
R
Board Pin 5
BROWN
N/A
S
Dual Schedule Receptacle-not used
N/A
N/A
T
Gun Switch
BLUE
8
U
Ground
GREEN/YELLOW
FRAME GROUND
V
Board Pin 6
ORANGE
N/A
19 PIN CONNECTOR FOR VA4000S
Keyway
A
M
L
K
U
N
B
C
P
V
T
J
H
S
R
D
E
F
G
Figure 4-3: Pin Identification Female Receptacle