ULTRAFEED VA 4000S

Manual No. 0-5135

4-3

OPERATION

12.32' CONTROL CABLE SOCKET: The 32' control cable connects to the VA 4000 S controller at the upper 19-pin

amphenol connector socket (of which 14 pins are used). It contains the signals required to allow the welding
power source, controller and the wire feeder to work together as a system. Refer to figure 4-3 and 4-4

WARNING

The protective earth ground (pin G) of the control cable is established only when the power source is
properly grounded. See the power source owner’s manual for proper grounding methods.

PIN LETTER

DESCRIPTION

WIRE COLOR

WIRE NUMBER

A

Motor Plus

RED

17

B

Motor Negative

BLACK

16

C

Gas Valve

BLUE

14

D

Gas Valve

WHITE

15

E

Board Pin 4

BLACK

N/A

F

Dual Schedule Receptacle-not used

N/A

N/A

G

Inch/Purge Common

RED

11

H

Purge

BROWN

10

J

Inch

YELLOW

9

K

Gun Switch

ORANGE

7

L

NOT USED

N/A

N/A

M

Board Pin 3

RED

N/A

N

Board Pin 2

YELLOW

N/A

P

Board Pin 1

WHITE

N/A

R

Board Pin 5

BROWN

N/A

S

Dual Schedule Receptacle-not used

N/A

N/A

T

Gun Switch

BLUE

8

U

Ground

GREEN/YELLOW

FRAME GROUND

V

Board Pin 6

ORANGE

N/A

19 PIN CONNECTOR FOR VA4000S

Keyway

A

M

L

K

U

N

B

C

P

V

T

J

H

S

R

D

E

F

G

Figure 4-3: Pin Identification Female Receptacle