27.GUN CLAMP KNOB: This knob is used to tighten the welding gun into the feedhead.

28.GUN ADAPTER: This adapter accepts the welding gun plug. It can optionally be replaced with different adapters

for a variety of different guns.

29.FEEDHEAD POSITIONING SCREW (3x): These screws are tightened to position the rotation angle of the feedhead.

To change the angle of the feedhead, LOOSEN these 3 screws and turn the feedhead to the desired angle. Then
tighten the 3 screws to secure.

30.INPUT WIRE GUIDE: This guide is required to direct the welding wire from the drive roll to the welding gun cable.

31.WELD CABLE CONNECTION: This is where the power source welding cable is connected to the feeder. Make sure

this connection is tight or arcing could occur.

22

23

24

25

26

27

28

21

Art # A-09224

24

29

30

31

Figure 4-6: Separation Feedhead Components

4.04 Power Source Compatibility

If the Thermal Arc power source only offers a 14 pin amphenol connector, a 870093B-001 adapter cable will be
required to connect between the 19 pin control cable of the VA 4000 S contoller and the 14 pin amphenol connector
of the power source.

The Ultrafeed VA 4000 S will also work with most competitive power sources that provide 115 VAC and require a relay
closure to become energized.