3 terminal commands, Erminal, Ommands – Tweco WC 1 Weld Sequence Controlle User Manual
Page 23

19
7.3 Terminal Commands
The following is a summary of the Terminal Commands supported by the WC 1:
COMMAND
PARAMETER DESCRIPTION
RANGE
UNITS
V1
Prepurge time
0-650.00
.01Sec.
V2
Arc start current
0-500
Amps
V3
Arc Start Wire feed speed
0-650
Ipm
V4
Arc Start delay time
0-650.00
.01 Sec.
V5
Ramp up Delay time
0-650.00
.01 Sec
V6
Run time current (Pulse Peak current)
0-650.00
Amps
V7
Run Time wire feed speed
0-650
Ipm
V8
Spot Weld Time (If Time=0 then Manual control)
0-650.00
.01 Sec.
V9
Percent Taper current
0-100
%
V10
Taper current delay time
0-650.00
.01 Sec.
V11
Ramp down delay time
0-650.00
.01 Sec.
V12
End current value
0-500
Amps
V13
End wire feed speed
0-650
Ipm
V14
End delay time
0-650.00
.01 Sec.
V15
Reverse wire speed time delay
0-650.00
Sec.
V16
Wire burn back delay time
0-650.00
.01 Sec.
V17
Post gas flow time delay
0-650.00
.01 Sec.
V18
Pulse current on time
.001 – 65.000
.001 Sec.
V19
Pulse current off time
.001 – 65.000
.001 Sec.
V20
Percent back ground current
0-100
%
V21
Jog wire feed speed
0-650
Ipm
Table 7 - Weld Process and Command Table