Tweco WC 1 Weld Sequence Controlle User Manual

Page 25

Advertising
background image

21

COMMAND

PARAMETER DESCRIPTION

RANGE

W1

Weld Schedule Mode Flag:
Bit 0 – Enable Pulse Weld Mode
Bit 1..7 – Not defined

0-255

W2

Active Weld Schedule number

1-32

W3

Active Weld Event number
0 -

Cycle Off

1 -

Cycle Start

2 -

Pre Purge

3 -

Start Time

4 -

Ramp Up Time

5 -

Run Time (Spot Weld Time if enabled)

6 -

Taper Current time

7 -

Ramp Down Time

8 -

End Time

9 -

Wire Reverse Time

10 -

Burn Back Time

11 -

Post Purge Time

0-11

W4

Write current schedule to specified weld schedule number

1-32

W5

Read specified weld schedule from memory to active schedule

1-32

Table 9 - Weld Mode Command Table

COMMAND

PARAMETER DESCRIPTION

RANGE

A1

Minimum Power supply current output (A1 = AMP

min

) used for DAC 1

scaling.

0-255

A2

Maximum Power supply current (A2=AMP

max

) used for DAC 1 scaling

Where: (DAC 1 Gain = [4000/( AMP

max

– AMP

min

)])

0-500

A3

Minimum Wire Feed speed (A3 = WIRE

min

) used for DAC 2 scaling

0-255

A4

Maximum Wire Feed Speed (A5=WIRE

max

) used for DAC 2 scaling

Where: (DAC 2 Gain = [4000/( Wire

max

– WIRE

min

)])

0-900

A5

Actual Setpoint value for DAC 1

0-500

A6

Actual Set point value for DAC2

0-900

Table 10 - Analog Scaling Command Table