Tweco 400 MST Arc Master User Manual

Page 45

Advertising
background image

400MST

9

ADVANCED TROUBLESHOOTING

9 – 8

1.3 Verification and Remedy to

Failures without Indication

Codes

Refer to Notes on Page 9-4.

1.3.1 "Cooling Fan Failure"

(Fan is not rotating)

Cause

Occurs when the cooling fan is defective, dam-

aged or the driving voltage is incorrect.

Verification/Remedy

a) Verify the cooling fan, FAN1.

•

Inspect the condition of the fan blades and all

peripheral parts. Clean the fan blades and all

peripheral parts if covered with dust. Clean-

ing and removing dust from the fan blades

once every 6 months in a normal environ-

ment is recommended. Extremely dusty envi-

ronments will require more frequent cleanings.

•

Verify that there are no wiring harnesses

entangled inside the fan, confirm that the har-

nesses do not have any brakes in the wire or

damaged connectors.

•

Contact the manufacturer if you find any

broken connectors or damaged wiring harn-

esses.

•

Replace the fan if there are any broken,

cracked or missing fan blades.

•

Refer to section 9.2.4.19 for replacement of

FAN1.

b) Verify the wiring harness between the cooling

fan (FAN1) and CN11 on PCB3 (WK-5548).

•

Confirm a secure connection of the harness

to CN11 on PCB3.

•

Contact the manufacturer if you find any

broken connectors or damaged wiring harn-

esses.

c) Cooling fan voltage tests and replacement of

the cooling fan (FAN1).

•

Follow the instruction in section 9.1.4.4.

1.3.2 "Wire feeding failure or inconsis-

tent wire delivery" (Wire feeder

does not work)

Cause

Power Source: Faulty or damaged 14-pin recepta-

cle and 19-pin receptacle, tripped or damaged

the circuit breaker (MCB1, MCB2), blown down-

transformer, associated wiring.

Wire Feeder: Feeder gear failure. Refer to the

wire feeder operator manual, supplied by the

wire feeder manufacturer, for additional informa-

tion.

Verification/Remedy

a) Confirm wire setting.
b) Verify CON1 of 14-pin receptacle (CON2 of 19-

pin receptacle). * Applies to MIG mode.

•

Confirm the wiring harness and connections

between CON1 of 14-pin receptacle (or

CON2 of 19-pin receptacle) and the wire

feeder device are secure.

•

Confirm the wiring harness and connections

between CON1 of 14-pin receptacle (or

CON2 of 19-pin receptacle) and PCB17 (WK-

5699).

•

Contact the manufacturer if you find any bro-

ken connectors or damaged wiring harn-

esses.

•  Confirm that the voltage between pin "I" and

pin "G" of the 14-pin CON1 receptacle is

AC115V (AC100~125V).

•  Confirm that the voltage between pin "E" and

pin "F" of the 19-pin CON2 receptacle is

AC115V (AC100~125V).

Advertising