2.09 WeldSkill 250 MIG Power Source Specifications

Description

WeldSkill 250 MIG

Plant Part Numbers

W1003400 & W1004500

Plant Dimensions

H 1050mm x W 470mm x D 1020mm

Power Source Mass

100kg

Cooling Fan

Cooled

Energy Input (Refer NOTE below)

This Column applies to the
Factory Fitted 2.5mm

2

(20A)

Primary Lead with 15A
Supply Plug

This Column applies to a

4.0mm

2

(25A) Primary

Lead with a 25A Supply
Plug.

Input Cable Requirements

Factory Fitted

4.0mm

2

2 core

+ earth

heavy duty R90 insulation
type

Nominal Supply Voltage

240VAC

240VAC

%

±

10%

±

10

Number of Phases

1

1

Nominal Supply Frequency

50Hz

50Hz

Effective Input Current (I

1eff

)

15 Amps

24 Amps

Maximum Input Current (I

1max

)

33 Amps

54 Amps

Single Phase Generator Requirement

8kVA

13kVA

Welding Current Range

50 – 190A

50 – 270A

Open Circuit Voltage Range

22 to 46 V

22 to 46 V

MIG (GMAW)
Welding Output, 40

o

C, 10 min.

190A @ 20%, 23.5V

110A @ 60%, 19.5V
85A @ 100%, 18.3V

250A @ 20%, 26.5V
144A @ 60%, 21.2V

112A @ 100%, 19.6V

Operating Temperature Range

0ºC - 40ºC

0ºC - 40ºC

Number of Output Voltage Switch Settings

12

Protection Class

IP21S

Table 2-1 WeldSkill 250 Specification

 

Table 2-1 WeldSkill 250 Power Source Specification

♥ The Effective Input Current should be used for the determination of cable size & supply requirements.
Motor start fuses or thermal circuit breakers are recommended for this application. Check local require-

ments for your situation in this regard.

♣ Generator Requirements at the Maximum Output Duty Cycle.
Reduced output ratings apply with the supplied 15A primary lead. To achieve the maximum rated output

& duty cycle ratings the 20A primary lead must be replaced with a larger primary lead as specified in

section 3.04. This must be carried out be a qualified electrical tradesperson.

NOTE

Due to variations that can occur in manufactured products, claimed performance, voltages, ratings,

all capacities, measurements, dimensions and weights quoted are approximate only. Achievable

capacities and ratings in use and operation will depend upon correct installation, use, applications,

maintenance and service.

Advertising
This manual is related to the following products: