3.01 Environment

These units are not designed for use in environments

with increased hazard of electric shock.
A. Examples of environments with increased hazard

of electric shock are:

1. In locations in which freedom of movement

is restricted, so that the operator is forced to

perform the work in a cramped (kneeling, sit-

ting or lying) position with physical contact with

conductive parts;

2. In locations which are fully or partially limited

by conductive elements, and in which there is

a high risk of unavoidable or accidental contact

by the operator, or

3. In wet or damp hot locations where humidity

or perspiration considerable reduces the skin

resistance of the human body and the insulation

properties of accessories.

B. Environments with increased hazard of electric

shock do not include places where electrically conduc-

tive parts in the near vicinity of the operator, which

can cause increased hazard, have been insulated.

3.02 Location

Be sure to locate the welder according to the follow-

ing guidelines:

1. In areas, free from moisture and dust.
2. Ambient temperature between 0ºC to 40ºC.
3. In areas, free from oil, steam and corrosive

gases.

4. In areas, not subjected to abnormal vibration or

shock.

5. In areas, not exposed to direct sunlight or

rain.

6. Place at a distance of 300mm or more from walls

or similar that could restrict natural air flow for

cooling.

7. The enclosure design of this power source

meets the requirements of IP21S as outlined in

AS 60529. This provides adequate protection

against solid objects, and direct protection from

vertical drops as outlined in the aforementioned

standard. Under no circumstances should the

unit be operated or connected in a micro envi-

ronment that will exceed the stated conditions.

For further information please refer to AS 60529.

3.03 Ventilation

Since the inhalation of welding fumes can be harmful,

ensure that the welding area is effectively ventilated.

3.04 Mains Supply Voltage

Requirements

The Mains supply voltage should be within 10% of

the rated Mains supply voltage. Too low a voltage

may cause poor welding performance. Too high a

supply voltage will cause components to overheat

and possibly fail.
The Welding Power Source must be:

• Correctly installed, if necessary, by a qualified

electrician.

• Correctly earthed (electrically) in accordance

with local regulations.

• Connected to the correct size power point and

fuse for each Power Source as per the Specifica-

tions on pages 2-6 and 2-7.

The WeldSkill 250 MIG Power Source is supplied with

a 20 Amp input lead and is designed for a 240 VAC

supply voltage.
The following Mains Current Circuit recommendations

are required to obtain the maximum welding current

and duty cycle from these welding products:

Mains Supply

Voltage

Setting

Mains

Supply

Lead Size

Minimum

Mains

Current

Circuit Size

Machines

Duty Cycle

240V

2.5 mm

2

15 Amp

190 A @ 20%

240V

4 mm

2

25 Amp

250 A @ 20%

Table 3-1 WeldSkill 250 Supply Requirements

NOTE

Motor start fuses or thermal circuit break-

ers are recommended for this application.

Check local requirements for your situa-

tion in this regard.