Tweco FP-235DC User Manual

Page 18

Advertising
background image

DC STRAIGHT POLARITY WELDING

The electrode in DC straight polarity (DCSP) welding is negative and the work surface is
positive. The current flow is from the electrode to the work.

Ideal Current for:

• Hard Facing.
• Build Up - Heavy Deposits.
• Cutting Steel.

ROD

METAL

AWS ROD NO.

USE

SIZE

AMPERAGE

THICKNESS

R52

Hard Surface

General Purpose

Tillage Tools

1/8”

80 - 140 amps

1/16” - Up

Subject to Impact and Abrasion

R88 Tung Rod

To Resist Serious Abrasion

1/8”

70 - 90 amps

1/16” - Up

ARC CUTTING

Cutting and Drilling All Metals

1/8”

80 - Max.

1/16” - Up

Drilling All Metals

E6011 Deep

1/8”

Maximum Dial

Any Thickness

Penetrating

5/32”

Setting

ARC GOUGING
E6011 Deep

Arc Gouging

5/32”

Maximum Dial

Any Thickness

Penetrating

DC REVERSE POLARITY WELDING

The electrode in DC reverse Polarity (DCRP) welding is positive and the work surface is negative. The current
flow is from the work to the electrode.

Ideal Current For:

• Overhead.
• Vertical.
• Cast Iron Welding.
• Heavy Aluminum.
• Rivet Welding.
• Sheet Metal.
• Low Hydrogen Welding.
• Arc Bronze Rod.

ROD

METAL

AWS ROD NO.

USE

SIZE

AMPERAGE

THICKNESS

E6011 Deep

Overhead and Vertical

1/8”

80 - 150 amps

1/8” - 1/2”

Penetrating

Welding or Rusty Metals

5/32”

100 - 170 amps

1/4” - Up

E7018 Low

High Carbon Spring Steel

1/8”

80 - 140 amps

1/8” - 1/2”

Hydrogen

or Cast Steel

5/32”

100 - 170 amps

1/4” - Up

ENiCl Nickel

Cast Iron

3/32”

50 - 70 amps

1/16” - 1/4”

Machineable

1/8”

80 - 120 amps

1/8” - Up

E308-16

Cast Iron

3/32”

50 - 100 amps

1/16” - 1/4”

Stainless Steel

Stainless Steel or Unknown
Metal Max. Strength

1/8”

90 - 150 amps

1/4” - Up

14

Advertising
This manual is related to the following products: