5. Remove all combustible materials from the work site. If you can not remove them, protect them with fire-

proof covers.

NEVER perform welding operations on a container that has held toxic, com-

bustible or flammable liquids or vapors. NEVER perform welding operations in an area con-
taining combustible vapors, flammable liquids or explosive dust.

VENTILATION

Ventilate welding work areas adequately. Maintain sufficient air flow to prevent

accumulation of explosive or toxic concentrations of gases. Welding operations using cer-
tain combinations of metals, coatings and gases generate toxic fumes. Use respiratory
protection equipment in these circumstances. BEFORE welding, read and understand the
Material Safety Data Sheet for the welding alloy.

ELECTROMAGNETIC COMPATIBILITY

BEFORE installing a MIG power source, inspect the surrounding area checking the following points:

1. Make sure there are no other power supply cables, control lines, telephone cables or other devices close to

the power source.

2. Make sure that telephones, televisions, computers or other control systems are not in the working area.

3. People with pace-makers or hearing aides should keep far from the power source. In particular cases, special

protection measures may be required.

Reduce interference by following these suggestions:

1. If there is interference in the power source line, mount an E.M.T. filter between the power supply and the

power source.

2. Shorten the output cables of the power source, keep them together and connected to ground.

3. Securely fasten the panels of the power source in place after performing maintenance.

HEALTH HAZARDS

The welding process can be hazardous to your health. Therefore, follow these precautions:

1. ALWAYS wear protective clothing without pockets and cuffs. Wear a helmet, gloves and shoes with an

insulating sole.

2. ALWAYS use a welding mask or helmet with the properly tinted protective glass in the shade adequate to

the welding operation being performed and to the current intensity.

3. Make certain that bystanders in the welding area are also following these precautions.

4. ALWAYS keep the welding mask glass clean. Replace it if it is cracked or chipped.

5. NEVER weld in a damp area or come in contact with a moist or wet surface when welding.

6. If the welding area lacks proper ventilation, use fume extractors.

7. Clean the welding pieces from solvents or greases which develop toxic gases when exposed to heat.

ELECTRIC SHOCK

ELECTRIC SHOCK CAN KILL! Reduce the risk of death or serious injury from

shock. Read, understand and follow ALL safety instructions. Be sure that everyone who uses
this welding equipment or who is a bystander in the welding area understands and follows
ALL safety instructions as well.