Section 5: service, 01 general maintenance, Section 5 – Tweco FP-38 Power Supply User Manual

Page 27: Service -1, 01 general maintenance -1

Advertising
background image

Manual 0-2967

5-1

SERVICE

SECTION 5:

SERVICE

5.01 General Maintenance

A. Each Use

Check torch consumables for wear, replace if necessary.

WARNING

Shut off power before inspecting or removing torch parts.

B. Every three months

A. Check internal air filter, replace if necessary.

1. Shut off input power; turn off the gas supply.

Bleed

down the gas supply.

2. Remove the upper cover screws.

3. Loosen the lower screws. Pull the cover up and

away from the unit.

NOTE

Leave internal ground wire in place.

Upper screws

Ground
wire

Lower screws

Upper screws

A-03285

Cover Removal

Advertising