Tweco SL100 User Manual

Page 4

Advertising
background image

Manual 0-2880

4

2. Adjust current output on the Power Supply to match

the selected tip and attach the work clamp firmly to

the work.

!

WARNING

Maximum current for is 60 Amps for SL60 Torches,

or 100 Amps for SL100 Torches. Operation of this

torch at higher outputs may damage the torch, the

leads, or the Power Supply. DO NOT operate the

SL60 Torch at more than 60 Amps, or the SL100

at more than 100 Amps.

CAUTION

Do not operate the torch with the torch tip in contact

with the work at outputs greater than 40 amps. Drag

cutting at higher output currents can cause irrepa-

rable damage to the torch parts. Use only shielded

parts at output currents higher than 40 amps.

3. Hold the torch away from your body.

4. Slide the trigger release toward the back of the torch

while simultaneously squeezing the trigger. The pilot

arc will start.

A-02986

Trigger

Trigger Release

5. Bring the torch within transfer distance to the work.

The main arc will transfer to the work, and the pilot

arc will shut off.

NOTE

The gas preflow and postflow are a characteristic

of the power supply and not a function of the torch.

3

4

Art # A-03383

Trigger

2

1

Trigger Release

6. Cut as usual. Simply release the trigger assembly to

stop cutting.

7. Follow normal recommended cutting practices as

provided in the power supply operator's manual.

NOTE

When the shield cup is properly installed, there is

a slight gap between the shield cup and the torch

handle. Gas vents through this gap as part of normal

operation. Do not attempt to force the shield cup to

close this gap. Forcing the shield cup against the

torch head can damage components.

8. The optional Standoff Guide allows the user to easily

adjust and maintain a consistent standoff height for

most applications.

Art # A-04063

Shield Cup

Standoff Guide

Torch Tip

Workpiece

Advertising
This manual is related to the following products: