9.3 Input and Output Signals

9.3.1 Input and Output Signals

(1) Input signals to the printer

•

DATA

: An 8-bit parallel signal. (Positive logic)

•

STB

: A strobe signal to read the 8-bit data. (Negative logic)

•

RESET

: A signal to reset the printer from the outside.(Negative logic)

(2) Output signals from the printer

•

ACK

: An 8-bit data request signal. A pulse signal output at the end of the BUSY signal.

(Negative logic)

•

BUSY

: A signal to indicate the BUSY status of the printer. Input new data when at

"LOW". (Positive logic)

•

FAULT

: A signal turned to "LOW" when the printer has an alarm. At this time, all the

control circuits in the printer stop. (Negative logic)

•

SELECT

: A signal to show whether the printer is selected(on-line) or deselected.(Positive

logic)

•

COMPULSION

: A signal to show the status of the drawer switch.(Positive logic)

•

PE :

A signal to show that the paper has run out. Normal at the "LOW" level, but turned

to the "HIGH" level when the paper has run out.

(3) Power related signal

•

GND

: Common ground on the circuits

•

Vcc

: A +5V signal. Connected via a 3.3k

Ω

resistor.