OSRAM SYLVANIA BackLED MB User Manual

Page 4

Advertising
background image

4

4.0

Troubleshooting Guide

Problem

Possible Cause

Corrective Action

Entire sign does not light

No input power

Check AC connection to power supply.

Entire sign/one or more LED

runs do not light

No power to LED

modules

Check power supply connection to modules.
Check DC polarity- power supply red output wires must be
connected to red striped module wires, power supply blue
output wires must be connected to gray striped module wires.

Verify power supply output voltage is 12V +/- 1.0V

Part of an LED run does not
light

No power to that run

Check module to module connection for correct polarity.

One module does not light

Module has been
damaged

Replace the module. Observe correct polarity.

Specifications subject to change without notice
OSRAM and OPTOTRONIC are registered trademarks of OSRAM GmbH
SYLVANIA is a registered trademark of OSRAM SYLVANIA Inc.
SEE THE WORLD IN A NEW LIGHT is a trademark of OSRAM SYLVANIA Inc.