LaMotte AM-21 Water Pollution Detection Outfit User Manual

Page 14

Advertising
background image

Field Test Method—Calcium Hardness

Procedure

1.

Fill the test tube (0769) to the 12.9 ml line with the sample water.

2.

Add six drops of *Sodium Hydroxide Reagent with Metal Inhibitors
(4259).

3.

Add one Calcium Hardness Indicator Tablet (5250). Cap and mix until
tablet is disintegrated. A red color will appear if calcium is present.

4.

Hardness Reagent #7 (4487) is added as described in the Field Test
Method for Total Hardness, until the red color changes to blue. The
results are read as Calcium Hardness in ppm CaCO

3

.

5.

The Magnesium Hardness level is determined by subtracting the
Calcium Hardness level from the Total Hardness level.

14