LaMotte OAKITE ALKALINE TEST KIT OKT 9205 User Manual

LaMotte Equipment

Advertising
background image

·

TEST KIT PROCEDURE 121

TITRATION OF OAKITE ALKALINE PRODUCTS WITH N ACID USING
PHENOLPHTHALEIN INDICATOR

(THIS PROCEDURE REPLACES PREVIOUS OAKITE PROCEDURE 92)

Test Kit: - OAKITE ALKALINE TEST KIT (CODE OKT 9205)

Reagents and Equipment:

Code

Quantity

Description

OKT 6130-J

100 ml

1 N Hydrochloric Acid

OKT 6131-J

100 ml

0.1 N Hydrochloric Acid

OKT 2246-G

25 ml

Phenolphthalein

OKT 2207-G

25 ml

Bromcresol Green

OKT 2292-G

25 ml

Methyl Red

0376

2

Direct Reading Titrator; 0-1 ml

0778

1

Titration Tube marked at 5, 10 and
15 ml, with cap

0354

1

Plastic dropper marked at 1 ml

Step 1:

Using the 1 ml dropper, pipet the appropriate sample volume of Oakite solution
listed in the table below into the empty titration tube. Add water to this solution
until the volume is at least to the 5 ml mark. For 5 and 10 ml sample volumes,
use the graduations on the titration tube. No water need be added.

Step 2:

Add 1 or 2 drops of Phenolphthalein Indicator. Swirl to mix. The color will be
red. Place the cap on the titration tube.

Step 3:

Fill the Direct Reading Titrator* to the zero mark with 1N Acid.

Step 4:

Insert tip of Titrator into the central hole in the titrating tube cap. While holding
the Titrator assembly in one hand, slowly depress the plunger of the Titrator
with the other hand to dispense the titrating solution. Swirl the solution gently
after each drop has been added. When the red color of the solution disappears
completely, stop any further movement of the plunger. Record the reading on
the Titrator in ml. Call this Titration T. This completes the analysis.

Calculation:

T x F = % by vol, g/

l

or oz/gal of Oakite product.

*NOTE:

For complete instructions on how to use the Direct Reading Titrator please
refer to the enclosed instruction sheet.

(con tin ued)

TK 121

Advertising