Troubleshooting – Wheatheart Remote PowerSwing User Manual

Page 17

Advertising
background image

W

HEATHEART

- R

EMOTE

P

OWERSWING

5. T

ROUBLESHOOTING

A232, A233, A234, A235,

AND

A236

MODELS

30664 R0

17

5. Troubleshooting

Problem

Possible Cause

Remedy

Hand held trans-

mitter does not

work.

Error with coding the transmitter or receiver.

Verify that coding is correct (see

Section 6. Appendix on page 19).

Contact a Westfield customer ser-
vice representative if problem per-

sists.

Manual switch

does not work.

Incorrect or faulty wiring of the switch.

Verify that wiring to switch is cor-

rect (see Section 2.2. Hydraulic

Configuration on page 10). If

problem persists, replace switch.

Valve only works in

one direction.

Incorrect wiring of the switch. *Incorrect wiring
may also blow the fuse in the junction box.

Verify that valve is wired correctly

(see Section 2.2. Hydraulic Con-

figuration on page 10).

Manual switch and

transmitter do not

work in either

direction.

Power not reaching junction box (white light on
the manual switch does not illuminate).

• Remove and insert the 7-pin

connector from the tractor to
ensure a good connection.

• Verify the solid connection of

the power supply wire in the
junction box of the Pow-
erswing.

• Open the 7-pin connector and

verify that the black wire is
attached securely to the termi-
nal labelled “blue”, and the
white wire to the terminal
labelled “white”.

Power reaching junction box (white light on the
manual switch is illuminated).

• Open the junction box and

check the 10-amp fuse.
Replace if there is any doubt
of its condition.

• Verify that the manual switch

is wired correctly (see Section
2.2. Hydraulic Configura-
tion on page 10). If wired
incorrectly, it can override all
functions.

• Verify that the valves are

wired correctly (see Section
2.2. Hydraulic Configura-
tion on page 10).

Advertising