Great Plains Mfg., Inc.

Front

Parts

Installation Instructions

7

2014-04-15

Front

Parts

194-033M

Connect Lift Circuit Hoses

Refer to Figure 9 (depicting 2012+ hoses - 2011- hoses are
MNPT-terminated without adaptors)
Note: Do not use thread sealant on JIC or ORB

connections.

Note: It may be necessary to loosen the FNPTS-MORB

adaptors

on the valve in order to tighten hose

NPT connections without twisting the hoses.
Alternatively, hoses can be disconnected at
cylinder-end JIC connections.

19. Connect the Transport Lift hoses

to the forward

valve ports (stamped “1B” and “2B”).

Connect the rod (retract) hose to the upper port
(stamped “1B”). Connect the base (extend) hose to
the lower port (stamped “2B”).

20. Connect the Opener Lift hoses

to the aft valve

ports (stamped “1A” and “2A”).

Connect the rod (retract) hose to the upper port
(stamped “1A”). Connect the base (extend) hose to
the lower port (stamped “2A”).

21. Connect the new common Lift hoses

to the

center (face) valve ports (stamped “1” and “2”).

Connect one hose to the upper port (stamped “1”).
Connect the other hose to the lower port
(stamped “2”).

22. Re-tighten any adaptor

or cylinder JIC

connections loosed for these steps.

U

D

F

B

L

R

B

A

23

20

Figure 9

Connect Hoses to Valve

27027

20

B

A

23

20

Advertising