Error code messages on the display module – Amico Nema 4 Master Alarm User Manual

Page 24

Advertising
background image

24

Amico Pipeline

SYMPTOM

CAUSE

CORRECTIVE ACTION

7. Gas reading incorrect.

b. Faulty display module.

a. Loose connection of DISS

fittings.

b. Sensor module is not properly

wired to the display module.

c. Defective sensor or requires

calibration.

d. The ribbon cable not properly

connected to the display module.

e. Defective display module.

2. If calibration is required, refer to

setting HIGH and LOW calibration

procedure on page 18/19.

1. Replace the display module.

1. Ensure that the sensor module

is properly connected to the DISS

demand check-valve.

1. Ensure that the sensor module is

properly wired to the display module

by using wiring diagram in Appendix

D or E.

1. Replace the sensor module.

1. Pull out the ribbon cable and connect

it back in again, while ensuring that it

is seated properly.

1. Replace the display module.

SYSTEM

CAUSE

CORRECTIVE ACTION

PAGE

E01

E02

E03

E04

E06

E07

No sensor is connected.

Sensor and Display Module mismatched.

The High set-point was set below the Low

set-point or vice versa.

Incorrect type of Sensor connected, (i.e. 250

Psi sensor on a 100 Psi range).

Cable between the sensor and display

module shorted out or reversed polarity.

Out of Calibration / Sensor not reading gas

Connect a sensor.

Ensure that the Sensor and Display Module

are for the same gas.

Recalibrate the High and Low setpoint to

proper values.

Connect the correct Sensor to the match-

ing Display Module.

Reverse polarity or replace cable if defective.

Replace the sensor module

41 / 42

19

15/16

41 / 42

41 / 42

Error Code Messages on the Display Module