Appendix p, Technical specification – Amico Nema 4 Master Alarm User Manual

Page 53

Advertising
background image

www.amico.com

53

Appendix P

Technical Specification

Supply Voltage:

115 to 220 VAC - 50 to 60 Hz

Current Draw:

1 Amp.Max.

Fuse (1/4 * 1-1/4): Fast Blow 1 Amp.

Cable requirement:

Area Display Module to Remote Sensor:

Distance:

Maximum 2,500 feet [750 m]

Cable:

Belden # 8451 or equivalent.
#22 gauge shielded, twisted pair. (For multiple sensors a multi-conductor
twisted pair, shielded cable should be used).

Signal:

30 VDC

-

1.0 Amps.

60 VDC

-

0.3 Amps.

125 VAC

-

0.5 Amps.

Master Module to Source equipment:

Distance:

Maximum 10,000 feet [3,000 m]

Cable:

Minimum #22 gauge wire (does not have to be shielded, twisted pair).

Signal:

5 VDC, < 5 µA.

Computer Interface Board:

Output:

Dry Contacts NC, open on Alarm.

Rating:

30 VDC

-

1.0 Amps.

60 VDC

-

0.3 Amps.

125 VAC

-

0.5 Amps.

Advertising