Edge Lighting Ice User Manual

Page 2

Advertising
background image

2

C

CONICAL NIPPLE

STRAIN RELIEF TUBE

COAXIAL CABLE

3

3: Feed the coaxial cable through the conical nipple and flared
side of the strain relief tube. Slide the conical nipple and
strain relief tube down the coaxial cable.

D

COAXIAL CABLE

4

4: Feed the coaxial cable into the coaxial fixture connector. The
coaxial cable will come to a stop point.

8: Push the strain relief tube completely into the coaxial
fixture connector. Make sure the slot on the strain relief
tube is not inline with the M4 set screw.

9: Tighten the M4 set screw with the 2mm Allen wrench.

F

8

9

2MM ALLEN WRENCH

M4 SET SCREW

STRAIN RELIEF TUBE

COAXIAL FIXTURE
CONNECTOR

E

1.5MM ALLEN WRENCH

M3 SET SCREW

WRINKLE

OUTER METAL JACK

INNER WIRE

5

6

7

5: Keep feeding the coaxial cable in until the inner wire is
visible in the screw hole of the fixture connector tip. The
outer metal jacket will start to wrinkle.

6: Hold the fixture connector in place. Replace and tighten the
M3 set screw on fixture connector tip with the 1.5mm Allen
wrench.

7: Pull down the outer metal jacket to smooth the wrinkles.

Advertising