3: Loosen the two M4 set screw on base of the coaxial fixture
connector with the 2mm Allen wrench provided. Do not
remove these set screws.

4: Remove the M3 set screw on tip of the connector with the
1.5mm Allen wrench provided.

D

M4 SET SCREW

M3 SET
SCREW

1.5MM ALLEN
WRENCH

2MM ALLEN
WRENCH

CONICAL NIPPLE

STRAIN RELIEF TUBE

3

4

E

5: Feed the coaxial cable through the conical nipple and flared
side of the strain relief tube. Slide the conical nipple and
strain relief tube down the coaxial cable.

6: Feed the coaxial cable into the coaxial fixture connector. The
coaxial cable will come to a stop point.

COAXIAL CABLE

COAXIAL CABLE

5

6

COAXIAL FIXTURE CONNECTOR

WRINKLE

OUTER METAL JACK

INNER WIRE

7

8

F

1.5MM ALLEN WRENCH

M3 SET SCREW

9

FIXTURE CONNECTOR

7: Keep feeding the coaxial cable in until the inner wire is
visible in the screw hole of the fixture connector tip. The
outer metal jacket will start to wrinkle.

8: Hold the fixture connector in place. Replace and tighten the
M3 set screw on fixture connector tip with the 1.5mm Allen
wrench.

9: Pull down the outer metal jacket to smooth the wrinkles.