Edge Lighting 2-Circuit Sloped Ceiling Surface Mount Magnetic Transformers User Manual

Page 3

Advertising
background image

3

10: Feed the extension wires through the transformer housing
center hole. Slide the transformer housing onto the
crossbar assembly nipple and secure it in place by
tightening the washer and inside nut.

E

11: Connect the black and white 120 volt wires from the top
transformer to one set of black and white extension
wires respectively with wire nuts.

12: Connect the black and white 120 volt wires from the top
transformer to the other set of brown and white extension
wires respectively with wire nuts.

13: Hook one of the transformer cover screw holes next to the
rectangle cutout, onto the Monorail feed contact set screw.

G

H

14: Place the transformer cover onto the transformer housing.
Replace and tighten the five M4 button head screws with
the 2mm Allen wrench.

13

MONORAIL 2 CIRCUIT
CONTACT SET SCREW

HOUSING

COVER

2MM ALLEN
WRENCH

14

M4 BUTTON
HEAD SCREW

WASHER

INSIDE NUT

EXTENSION WIRES

HOUSING

CROSSBAR ASSEMBLY
NIPPLE

14

14

M4 SET
SCREW

CONNECTOR

15

15

I

2MM ALLEN WRENCH

15: (OPTIONAL) To change the direction of the Monorail 2
Circuit, loosen the M4 set screw (Do Not Remove) on the
sloped connector. Rotate the Monorail 2 Circuit connector to
desired direction. While pushing the Monorail 2 Circuit
connector to the sloped connector, tighten the M4 set screw
with the 2mm Allen wrench.

SLOPED CONNECTOR

F

11

12

TOP TRANSFORMER

BOTTOM
TRANSFORMER

10

NOTE:

disconnected & capped.

The yellow input wires are not used. Leave these wires