Install the transformer, Connect the 12 volt low voltage wires, Low voltage wire size chart – Edge Lighting 600W/12V Remote Recessed Transformer User Manual

Page 2: Terminal tap chart

Advertising
background image

LOW VOLTAGE WIRE SIZE CHART

2

Install the Transformer

1: Select the location between the wall studs (16" apart) where
the transformer is to be mounted.

2: Place the transformer between the studs and fasten it to the
studs through the bracket holes with four #8 or #10 screws
(not provided).

A

STUD

T2

T3

T4

T1

SCREW

BRACKET

2

Connect the 12 Volt Low
Voltage Wires

2: Insert one low voltage wire into the

terminal and

tighten the screw firmly. Mark this low voltage wire in
the electrical box as "COM1".

3: Insert the second low voltage wire into the "COM2" terminal
and tighten the screw firmly. Mark this low voltage wire in
the electrical box as "COM2".

4: Insert the last two low voltage wires into the "T2" terminal
(default) and tighten the screws firmly. Mark these low
voltage wires in the electrical box as "HOT1" and "HOT2".

5: Measure the voltage at the power wires coming into the
transformer. If the voltage is not in the range of 115-120
volt, then pick the proper terminal tap using the "Terminal
Tap Chart" below to reconnect the last two low voltage wires.

6: Install drywall.

"COM1"

TRANSFORMER
WATTAGE

WIRE SIZE
FOR 5 FT

WIRE SIZE
FOR 6-15 FT

WIRE SIZE
FOR 16-20 FT

WIRE SIZE
FOR 21-40 FT

300 WATT

#10 GA

#6 GA

#4 GA

#1 GA

TERMINAL TAP CHART

PRIMARY POWER
INPUT VOLTAGE

TERMINAL TAP
TO BE USED

105-109

T4

110-114

115-120

121-125

T3

T2

T1

COM 1

COM 2

T2

T3

T4

T1

COM 1

COM 2

B

1

LOW VOLTAGE
WIRES

COM1

HOT2

COM2

HOT1

4

3

2

1: Install four THHN low voltage wires from the transformer
to the electrical box to which the power feed canopy will be
attached. Run the proper size wire using the "Low Voltage
Wire Size Chart" below.

NOTE: The THHN wire sizes specified in "Low Voltage Wire Size
Chart" are for 3% or less drop in voltage based on 300 watt
loads. Lengths are the distance from the recessed transformer to
the system power feed connector, or power feed canopy.

ELECTRICAL BOX

NOTE: Using a smaller wire size other than specified will result in
a increase in voltage drop and will reduce the lamp intensity.