Shortening the power feed rod height – Edge Lighting 600W/24V Surface Mount Magnetic Transformer User Manual

Page 5

Advertising
background image

POWER
FEED ROD

M3 SET
SCREW

1.5MM ALLEN
WRENCH

BUSHING

5

L

1: Remove the wire nut from the center wire.

2: Loosen (DO NOT REMOVE) the bottom M3 set screw on
the bushing and carefully pull out the power feed rod along
with the center wire.

Shortening the Power Feed Rod Height

POWER FEED ROD

M

3: From the end of the power feed rod mark the rod to the
amount that needs to be shorten. For example to resize 24"
standoff to 17", mark 7" from the end of the power feed rod.

3

POWER FEED ROD

N

4

4: Use a pipe cutter to cut out the excess rod. If cutting with a
hacksaw, then make sure the center wire is removed from
the rod. To remove the center wire, remove the power feed
cap, pull the wire out. Make sure to clean the burr of the cut
section before re-feeding the center wire.

PIPE CUTTER

POWER HOUSING

O

5: Feed the center wire through the bushing inserting the
power feed rod completely inside the bushing. Tighten
the bottom M3 set screw with the 1.5mm Allen wrench.

6: Connect the center wire to the loose transformer wire with a
wire nut.

7: Follow the "Install the Surface Mount Transformer" steps on
page 2.

POWER FEED CAP

2

1

POWER
FEED ROD

M3 SET
SCREW

1.5MM ALLEN
WRENCH

BUSHING

5

1

6