Edge Lighting 2x150W/12V Dual Feed Surface Mount Magnetic Transformer User Manual

Page 4

Advertising
background image

4

Install the Monorail 2 Circuit Sections to the Transformer

I

STRAIGHT
CONDUCTIVE
CONNECTOR

1

ONE MONORAIL 2 CIRCUIT SECTION

MONORAIL 2 CIRCUIT
FEED CONTACT

SURFACE
TRANSFORMER

3

2

MONORAIL

SECTION

2

CIRCUIT

NOTE:

before connecting the Monorail 2 Circuit to the transformer (refer
to the instructions provided with the Monorail 2 Circuit 1"
standoffs).

The Monorail 2 Circuit 1" standoffs should be installed

1: Push one end of the straight conductive connectors
(provided with the transformer) completely into one end of
the Monorail 2 Circuit section.

Monorail 2 Circuit

Monorail 2

Circuit

While supporting the Monorail 2

Circuit section by hand connect this section to the Monorail 2
Circuit 1" standoffs (refer to the instructions provided with
the Monorail 2 Circuit 1" standoffs).

Monorail 2 Circuit

2: Push the end of the straight conductive connectors (along
with the

) completely into one

feed contact.

3: Repeat steps 1 & 2 for the second

section.

SECOND MONORAIL

SECTION

2 CIRCUIT

NOTE:

connected together by the Monorail 2 Circuit feed contacts.

The two Monorail 2 Circuit feed sections are electrically

SWITCH 1

J

SWITCH 2

HOT 1

HOT 2

COM

HOT 2

HOT 1

COM

NOTE:

Switch 2 turns on/off circuit 2 (COM & HOT 2). Load each circuit of
Monorail 2 Circuit to MAXIMUM 150 watt.

Switch 1 turns on/off the circuit 1 (COM & HOT 1) and

4: If using only one Monorail 2 Circuit section then plug the
unused Monorail 2 Circuit feed contact with the plastic insert
provided

K

MONORAIL FEED
CONTACT

PLASTIC
INSERT

4

Advertising