Install drywall, trim & lamp – Edge Lighting Vision 8 User Manual

Page 2

Advertising
background image

2

6: Remove a knock out to install the power line conduit.

7: Install the conduit and run the power line wires to the
housing.

8: Make sure that the housing is grounded in accordance with
local electrical codes.

9: Connect the white transformer wire to the neutral power
line wire with a wire nut.

10: Connect the black thermal protector wire to the hot power
line wire with a wire nut.

11: The black transformer wire is connected by default to the
other wire of the thermal protector.

B

STUD

HOUSING

THERMAL
PROTECTOR

TRANSFORMER

CONDUIT

9

10

8

Install Drywall, Trim & Lamp

C

2.5"

2

8.25"

1

1: Mark a 2.5" wide by 8.25" high rectangle on the drywall
where the housing opening is located.

2: Cut out the marked rectangle and install the drywall.

3: After installing drywall and finishing it, remove the cover on
the terminal block to expose the screws.

4: Loosen the two bottom Phillips screws on the terminal
block and the two on the strain relief (Do Not Remove).

5: Insert blue transformer wire through the strain relief
and one into each terminal block hole. Tighten the Phillips
screws on the terminal block and strain relief.

6: Replace the terminal block cover.

D

DRYWALL

TRIM

COVER

TERMINAL
BLOCK

STRAIN
RELIEF

7

3

5

Advertising