Edge Lighting PSB-400W-24VDC-RGB, 400 Watt 24 Volt DC Power Supply User Manual

Page 2

Advertising
background image

Installing LED Power Supply with RGB Soft Strip & CDP or
CTP Controller

1: Loosen the four Phillips screws on the front of the power
supply cover to slide the cover off of the case.

2: Carefully pull off the cover from the DVR-RGB-200 driver.

A

COVER

1

CASE

M

DVR
DRIVER

COVER

2

PHILLIPS
SCREW

B

ELECTRICAL BOX

CONTROLLER

CONTROLLER POWER SUPPLY

CONDUIT

CASE

8

DMX CABLE

DMX CABLE
(BELDEN #9841)

4

6

7

3: Connect one end of a red wire to “VDC+” of the controller
terminal and the other end of the red wire to the “+24VDC”
of the power supply terminal.

4: Connect one end of a black wire to “Ground” of the controller
terminal and the other end to the “-24VDC” of the power
supply terminal.

5: Run the black and white line voltage wires coming from
the controller power supply to the power supply case.

6: Connect the white wire to "N" terminal of the controller
power supply.

7: Connect the black wire to "L" terminal of the controller
power supply.

8: Install conduits from controller, main panel (line voltage),
and soft strip to power supply.

9: Run proper DMX cable (Belden #9841 recommended)
with three data wires from controller to the power supply
box.

NOTE: Use a deep double gang boxes to fit the controller
and controller power supply (OT-20-120-240-245
recommended).

2

9

NOTE: Refer to the "Configuring DimWheel" & "Operating
DimWheel" on page 6 & 7 to properly operate the controller.

3

Advertising