Relocating soft strip (optional), Overall wiring diagram – Edge Lighting SS2P Soft Strip, 2.3W 24VDC High Output User Manual

Page 2

Advertising
background image

2

E

ALUMINUM TAPE

11

LED SOFT STRIP

POWER
SUPPLY

DIRECTIONAL
CONNECTOR

END CAP

10

D

7: Add the other piece of soft strip by simply connecting female
end of the soft strip to the male end of the new soft strip
directly or with interfacing of the directional connectors.

8: The 1" long soft strips can be used for fine adjustments.

FEMALE END OF
SOFT STRIP

MALE END OF
SOFT STRIP

7

DIRECTIONAL
CONNECTOR

7

9: Use the optional end cap to cover the end of the soft strip.

10: The excess amount of soft strip can be cut by the indicated
sections of the run with a pair of scissors. Once the soft
strip is cut, it cannot be extended.

11: Install the power supply by referring to the instructions
provided with the power supply.

NOTE: SS2 soft strip consumes on average 2.3 Watt per foot.

+24VDC

+24VDC

9

+24VDC

9

+24VDC

+24VDC

+24VDC

+24VDC

SOFT STRIP

F

1: To remove the tape residue from back of the strip apply
moderate amount WD-40, or Goo Gone, or a mixture of
warm water and lemon oil to the corner of a clean, dry
towel. Gently buff the area containing the adhesive residue
with small circular motion until it is completely removed.

2: From one side of the tape gently remove a few inches of the
backing. Attach the adhesive tape to the back of the soft
strip and apply moderate pressure to affix the tape. Continue
this step a few inches at the time until the entire adhesive
tape is attached to back of the soft strip.

3: Refer to the steps on 1 through 11 to reinstall the soft strip.

NOTE: If relocating the installed soft strip, make sure that the
adhesive tape on back of the soft strip covers the entire strip. The
adhesive tape on back of the soft strip isolates the strip from the
conductive heat sinks. Damaged or inconsistent adhesive tape may
cause the contacts on the back of the strip to come in contact with
the conductive heat sink which will cause the strip to short and
burn. Call Edge Lighting to get replacement adhesive tape and
aluminum heat sink tape (SS-HR-F)

SOFT STRIP

ADHESIVE TAPE

REMOVE SOFT STRIP
TO RELOCATE

APPLY ADHESIVE REMOVER
AND THEN BUFF OFF

ADHESIVE TAPE

ADHESIVE BACKING

ADHESIVE

BACK SIDE OF
SOFT STRIP

1

2

Relocating Soft Strip (Optional)

LED SOFT STRIP

BLACK

POWER SUPPLY

WHITE

120V NEUTRAL

120V HOT

YELLOW

Overall Wiring Diagram

Advertising