Replacement parts, Installation, Trouble - shooting – Kraus C-KCV-150-14301 User Manual

Page 2

Advertising
background image

1 3/8’’

O

4

3

2

1

6

5

Insert the lift pole 9 through the hole at
the back of the faucet body 1.

Faucet body

Fixing bolt

Waterlines

O-ring

Rubber washer

Brass washer

Nut

1.

2.

3.

4.

5.

6.

7.

Replacement Parts

Keep this manual for ordering replacement parts.

Trouble - Shooting

Problem

Cause

Action

Leaks underneath handle

Aerator leaks or has an inconsistent
water flow pattern.

Water will not shut off completely.

Adjusting ring or cap has come loose.

Aerator is dirty or misfitted.

Dirty or worn out plastic washer in the
cartridge.

Tighten the adjusting ring or cap.

Unscrew the aerator to check rubber packing
or replace the aerator.

Remove handle and cartridge to check if ceramic
disk is damage permanently or dirty.
Re-install cartridge.

Contact Us Toll-Free at 1-800-775-0703; or visit our website at www.kraususa.com 2008-2011 Kraus USA Inc.

Installation

Contact Us Toll-Free at 1-800-775-0703; or visit our website at www.kraususa.com 2008-2011 Kraus USA Inc.

1

2

3

4

5

6

7

8

9

10

Spanner

Lift pole

Drain off pole

8.

9.

10.

Screw waterlines 3 into the inlet
pipe of the faucet body 1.
Fit O-ring 4 into the bottom
groove of Faucet body 1.

Insert waterlines 3 and fixing bolt 2 into the set hole
of the under mount sink or 1 3/8”drilled hole of the
counter top. Put on the rubber washer 5 and brass
washer 6 then securely tighten with nut 7. Place the
faucet body 1 and use the spanner to tighten the
nut 7 securely.

Insert the drain-off pole 10 through the hole of the basin.
Tighten the drain-off pole 10 securely. Place the end side of
the lift pole 9 through the drain-off pole 10 and then tighten
the screw.