Baumer GB-GXxxx User Manual

Page 10

Advertising
background image

Manual_EtherCAT_PoE_BIDE_EN.doc 10/19

Baumer IVO GmbH & Co. KG

11.11.10

Villingen-Schwenningen,

Germany

Object 0x1011 RESTORE Application Parameter

Object 0x1011 restores ROM default in device-specific objects (0x6000..0x6FFF) both in RAM and EEPROM. To
prevent any inadvertent restore, the signature „load“ must be written in object 0x1011 Subindex 0.

Signature

MSB

LSB

ISO 8859 character
hex

Object 0x1018 Identity Object

SubIndex 0
Data type

Unsigned 8

Access ReadOnly
Default 4
EEPROM No
Significance Maximum supported subindex
Values

4 = Maximum supported subIndex


SubIndex 1
Data type

Unsigned 32

Access ReadOnly
Default Ech
EEPROM No
Significance

VendorID for Baumer IVO GmbH & Co. assigned by CiA

Values

0xEC (in the Internet under www.can-cia.de)


SubIndex 2
Data type

Unsigned 32

Access ReadOnly
Default 0x0A

Æ

GXMMW_H ; 0x0B Æ GXAMW_H

0x0C Æ GCMMW_H ; 0x0D Æ GCAMW_H
0x0E Æ GBMMW_H, GDMMW_H ; 0x0F Æ GBAMW_H, GDAMW_H

EEPROM No
Significance Product

Code

Values

SubIndex 3
Data type

Unsigned 32

Access ReadOnly
Default
EEPROM No
Significance

Revision no.

Values

SubIndex 4
Data type

Unsigned 32

Access ReadOnly
Default

EEPROM No
Significance

Serial no.

Values

d a o l

0x64 0x61 0x6F 0x6C

Advertising