4 Encoder operating parameters

Significance of operating parameters

Product

Product
family

Resolution per

turn

Number of turns

Measuring range

Decimal

Hex

Bit

Decimal

Hex

Bit

Decimal

Hex

Bit

GCAMW(S)

magtivo

®

4096 1000

12

1

1

0

4096

1000

12

GCMMW(S)

magtivo

®

4096 1000

12

65536

10000

16

268435456 10000000

28

GDAMW(S)

activo

®

262144 40000

18

1

1

0

262144

40000

18

GDMMW(S)

activo

®

262144 40000

18

16384

4000

14 4294967296 100000000

32

GXAMW(S)

multivo

®

8192 2000

13

1

1

0

8192

2000

13

GXMMW(S)

multivo

®

8192 2000

13

65536

10000

16

536870912 20000000

29

GBAMW(S)

multivoPlus

262144 40000

18

1

1

0

262144

40000

18

GBMMW(S)

multivoPlus

262144 40000

18

16384

4000

14 4294967296 100000000

32



These are ROM default parameters upon delivery.

Firmware version (0x100A) V4.00 provides a scaling function for customer-specific parameterization
of resolution, total measuring range, direction of rotation and preset. Refer also to chapter SDO,
object 0x6000.