Baumer GB-GXxxx User Manual

Page 14

Advertising
background image

Manual_EtherCAT_PoE_BIDE_EN.doc 14/19

Baumer IVO GmbH & Co. KG

11.11.10

Villingen-Schwenningen,

Germany

5.5 Distributed Clocks Mode

Distributed clocks mode enables exactly the same time with all bus users.
The encoder can be utilized and configurated as reference clock for synchronisation purposes of both other
users and master. Thus a high-precision time base is available throughout the network.
The encoder generates process data synchronously to a Sync Signal .

5.5.1 Activation Distributed Clocks under TwinCAT


















Afterwards E/A devices reload
(F4) is mandatory


5.6 Network

management

The encoder state machine can be switched over by online in the TwinCAT system manager (similar to
network management at CANopen)

Advertising