INSTALLATION REQUIREMENTS

NOTE

For installations requiring a longer drain hose, have

a qualifi ed technician install a longer drain hose

(according to your model number) available from an

authorized parts distributor. For drain systems in the

fl oor, install a syphon break kit available from your local

hardware store.

Installation in a Recess or Closet

If washer and dryer are installed in the same closet, door

ventilation is required: A minimum of 120 square inches

(774.2 cm²) of opening, equally divided at the top and

bottom of the door, is required. Louvered openings should

be located 3 inches (7.6 cm) from bottom and top of

door. Air openings are required to be unobstructed when

a door is installed. A louvered door with equivalent air

openings for the full length of the door is acceptable.

60 sq. in.

(387.1cm²)

3”

(7.6cm)

60 sq. in.

(387.1cm²)

3”

(7.6cm)

closet door

Drain system requirements

1 Drain capable of eliminating 17 gals (64.3 L) per

minute.

2 A standpipe diameter of 1-1/4 in. (3.18 cm)

minimum.

3 The standpipe height above the fl oor should be:

Minimum height: 36 in. (91 cm)

Maximum height: 96 in. (244 cm)

96”

(244 cm)

max.

36”

(91 cm)

min.