Installation requirements, Important, Warning – FRIGIDAIRE FFLG2022MW User Manual

Page 10: Laundry center dimensions, Clearance requirements

Advertising
background image

10

Laundry Center Dimensions

47.5” (120.5 cm)

31.5” (80 cm)

27” (68.5 cm)

76”

(193 cm)

12”

(30.5 cm)

37”

(94 cm)

54.75”

(139 cm)

42.5”

(108 cm)

4 in. (102 mm)

exhaust vent

on rear of unit

center line height

for 4 in. (102 mm)

exhaust outlet

drain hose reten-

tion clamp on rear

of washer

2

water supply

connection on

rear of washer

power cord

attachment

location on rear

of unit

1

17.6”

(45 cm)

1

Power supply cord length on gas unit approximately 60 inches (152.5 cm).

2

Loose drain hose length beyond clamp approximately 52 inches (132 cm).

44”

(112 cm)

9.4”

(24 cm)

5.5”

(14 cm)

gas supply

pipe on rear

of gas unit

MINIMUM INSTALLATION CLEARANCES - Inches (cm)

SIDES

REAR

TOP

FRONT

Alcove

0”

(0 cm)

0”

(0 cm)

1”

(2.5 cm)

n/a

Closet

0”

(0 cm)

0”

(0 cm)

1”

(2.5 cm)

1”

(2.5 cm)

Clearance requirements

0”

(0 cm)

0”

(0 cm)

1”

(2.5 cm)

1”

(2.5 cm)

INSTALLATION REQUIREMENTS

IMPORTANT

DO NOT INSTALL YOUR LAUNDRY CENTER:
1 In an area exposed to dripping water or outside weather conditions. The ambient temperature should never

be below 60° F (15.6° C) to maximize detergent effectiveness.

2 In an area where it will come in contact with curtains, drapes, or anything that will obstruct the fl ow of

combustion and ventilation air.

3 On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.5 cm). To minimize vibration or movement,

reinforcement of the fl oor may be necessary.

WARNING

EXPLOSION HAZARD

Do not install the dryer where gasoline or other

fl ammables are kept or stored. If the dryer is installed

in a garage, it must be a minimum of 18 inches (45.7

cm) above the fl oor. Failure to do so can result in

death, explosion, fi re or burns.