1 Turn off power supply to outlet.
2 Remove the screw securing the terminal block

access cover on the back of the dryer.

3 Install a UL-approved strain relief according to the

power cord/strain relief manufacturer’s instructions

in the power cord entry hole below the access

panel. At this time, the strain relief should be

loosely in place.

4 Thread an UNPLUGGED, UL-approved, 30 amp.

power cord, NEMA 14-30 type ST or SRDT, through

the strain relief.

5 Disconnect the internal (WHITE) dryer harness

ground wire from the (GREEN) ground screw next

to the terminal block.

6 Attach the ground (GREEN) power cord wire to the

cabinet with the ground (GREEN) screw. Tighten

the screw securely.

7 Move the internal dryer harness ground (WHITE)

wire to the terminal block and attach it along with

the neutral (WHITE) power cord wire conductor

to the center, SILVER colored terminal on the

terminal block. Tighten the screw securely.

8 Attach the RED and BLACK power cord conductors

to the outer, BRASS colored terminals on the

terminal block. Tighten both screws securely.

9 Follow manufacturer’s guidelines for fi rmly securing

the strain relief and power cord.

10 Reinstall the terminal block cover.

Move internal ground

(WHITE) wire to neutral

(silver) terminal for

4-wire system

Neutral

terminal

BLACK

or RED

power wire

BLACK

or RED

power wire

WHITE

neutral wire

GREEN

ground wire

GREEN

ground screw

4-wire receptacle

(NEMA type 14-30R)

Neutral

Neutral

(WHITE wire)

(WHITE wire)

30 AMP

30 AMP

NEMA 14-30

NEMA 14-30

Ground

Ground

(GREEN wire)

(GREEN wire)

Electrical connection (non-Canada) - 4 wire cord

WARNING

ELECTRICAL SHOCK HAZARD

Failure to disconnect power source before servicing

could result in personal injury or even death.

WARNING

ELECTRICAL SHOCK HAZARD

Do not make a sharp bend or crimp wiring/conductor

at connections.

INSTALLATION INSTRUCTIONS

Advertising
This manual is related to the following products: