Installation, Calculating duct length table – FRIGIDAIRE FH30DD50MS User Manual

Page 12

Advertising
background image

DUCT PIECES

EQUIVALENT

LENGTH X

NUMBER

USED =

EQUIVALENT

LENGTH

6" (15.2cm) Round

Straight **

1 Ft. (0.3m)

Ft. or m

6" (15.2cm) Round Metal Flex

No Bends **

1.5 Ft. (0.45m)

Ft. or m

6" (15.2cm)

90° Elbow

10 Ft. (3m)

Ft. or m

6" (15.2cm)

45° Elbow

5 Ft. (1.5m)

Ft. or m

3¼" x 10" (8.2cm x 25.4cm)

Straight **

1 Ft. (0.3m)

Ft. or m

3¼" x 10" (8.2cm x 25.4cm)

90° Elbow

10 Ft. (3m)

Ft. or m

3¼" x 10" (8.2cm x 25.4cm)

45° Elbow

5 Ft. (1.5m)

Ft. or m

3¼" x 10" (8.2cm x 25.4cm)

90° Flat Elbow

10 Ft. (3m)

Ft. or m

3¼" x 10" (8.2cm x 25.4cm) to 6"

(15.2cm) Round Transition 90° Elbow

30 Ft. (9m)

Ft. or m

6" (15.2cm) Round to 3¼" x 10"

(8.2cm x 25.4cm) Transition

90° Elbow

30 Ft. (9m)

Ft. or m

3¼" x 10" (8.2cm x 25.4cm) to 6"

(15.2cm) Round Transition

5 Ft. (1.5m)

Ft. or m

6" (15.2cm) Round to 3¼" x 10"

(8.2cm x 25.4cm) Transition

5 Ft. (1.5m)

Ft. or m

6" (15.2cm) Round Wall Cap with

Damper

30 Ft. (9m)

Ft. or m

3¼" x 10" (8.2cm x 25.4cm) Wall

Cap with Damper

30 Ft. (9m)

Ft. or m

6" (15.2cm) Round Roof Cap

30 Ft. (9m)

Ft. or m

TOTAL DUCTWORK

Ft. or m

** For Straight Round / Rectangular Duct, measure actual linear feet

used and then multiply by Equivalent Length shown.

Calculating Duct Length Table

For maximum efficiency, use the shortest and straightest duct possible. The system will operate most efficiently when

the ductwork does not exceed 60 feet of equivalent duct. The downdraft will operate properly with ductwork up to 100

equivalent feet of duct.
Calculations are approximate and based on HVAC industry standards.

12

INSTALLATION