Planning, Basic information, Take measurements – FRIGIDAIRE FH30DD50MS User Manual

Page 6: Caution, Typical installation

Advertising
background image

6

PLANNING

Basic Information

A qualified technician must complete the installation of this

appliance. This downdraft blower system is designed to be

used to exhaust airborne contaminants when cooking with

a variety of gas, electric or induction cooktops.
It can be mounted in island, peninsula, or conventional

wall locations.
This unit is installed following these basic steps:
• Cut out the countertop opening.

• Mount the unit in the cabinet.

• Connect the ductwork and electrical.

• Install the cooktop.

Take Measurements

Refer to the cooktop installation instructions for dimensions

of the cooktop, countertop cut-out and cabinet requirements.

It is recommended that oversized cabinets be used for easier

installation.
Cooktop depth can vary greatly from one unit to another.

This may cause the fit of the cooktop and the telescopic

downdraft appliances to be tight in the countertop depending

upon the overall depth of the countertop.

Countertop

Cooktop

Chassis

Housing

Front to back

Inside cabinet depth

2

5

/

16

(5.8 cm)

2

1

/

16

(5.2 cm)

1

/

8

(0.3 cm)

Countertop

A

B

Cooktop

Chassis

Housing

Front to back

Inside cabinet depth

2

5

/

16

(5.8 cm)

2

1

/

16

(5.2 cm)

1

/

8

(0.3 cm)

1

/

4

Min.

(0.6 cm)

1

/

4

Min.

(0.6 cm)

clearance

behind

downdraft

CAUTION

The high level of air flow of this appliance may affect the

gas flame on some gas cooktop models. Extreme caution

must be used to assure proper flame is generated and

maintained through the operating range of the vent.

Refer to cooktop Installation Instructions and Use and

Care guide for proper gas burner setup. Gas Cooktop

installation and service must be performed by a qualified

installer, service agency or gas supplier.

NOTE

Preformed countertops with a raised lip and/or backsplash

as illustrated in (A) or (B) may not allow enough flat

countertop for proper installation. Note that a minimum

of 2

5

/

16

” of flat countertop is required behind cooktop

and that 2

1

/

16

” is necessary between the back edge of

the cooktop and the inside of cabinet back.

Typical Installation

5-7/8” Minimum

(14.9 cm)

10-13/16”

(27.5 cm)

4-1/2”

(11.4 cm)

Chassis Housing

Downdraft

Top Trim

Cooktop

Countertop

Blower & Motor

Maximum gap to

cabinet back allowed

before installation of a

wood support is

required for mounting

stabilizing brackets

Advertising
This manual is related to the following products: