Installing the 1 x 2 SCSI Module

www

.dell.com | support.dell.com

5

Slide the drive tray to the maintenance position.

a

Use a #2 Phillips screwdriver to loosen the captive screw that secures the drive tray
release handle to the chassis.

b

Rotate the drive tray release lever toward the front of the system.

c

Grasp both sides of the front panel and slide the drive tray towards the front of the
system until the tray is in the maintenance position.

Installing the Drive Cage

1

Locate the insert tab above the center filler plate. See Figure 1-1.

2

Press the insert tab and remove the center filler plate from the peripheral bay. See Figure 1-1.

NOTE:

If a tape drive is not installed in your system, do not remove the top filler plate.

Figure 1-1.

Peripheral Bay Filler Plates

3

Locate the black square on the lower filler plate. See Figure 1-1.

4

Place your right thumb on the black square, reach behind the lower filler plate, squeeze
the lower filler plate release lever, and remove the filler plate from the peripheral bay.

center filler plate

top filler plate

lower filler plate

insert tab

black square

thumbscrew

cam handle