TECHNICAL DATA

DIMENSIONS
Height

900 - 915mm

Width

1000mm

Depth

600mm (excluding door handles)

GENERAL
Gas connection

Rp

1

/

2

(

1

/

2

” BSP female)

Pressure test point

Hotplate burner injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

Flexible cord fitted with a 13A plug
230/240V a.c. 50Hz 3A fuse.

INSTALLATION INSTRUCTIONS

HEAT INPUT HEAT INPUT

BURNER

INJECTOR

Cat I

2H

G20 at 20 mbar

240V a.c.

GRILL

LEFT OVEN

RIGHT OVEN

0.22 kW

WARMING
COMPARTMENT

2.0 kW

HOTPLATE
Front Left

102

3.0 kW

HOTPLATE
Rear Left

128

HOTPLATE
Centre Rear

72

5.1 kW

1.0 kW

1.65 kW

1.65 kW

HOTPLATE
Centre Front

2 x 110

1 x 74

3.9 kW

HOTPLATE
Front Right

135

2.5 kW

HOTPLATE
Rear Right

115

2.5 kW

115

88

88

26

Advertising