Controlling power of a kvm-connected server, Eb manager – “to power on, power, Remote computer – Cyclades User's Guide User Manual

Page 351

Advertising
background image

Accessing Connected Devices

335

Controlling KVM Port Connections

Controlling Power of a KVM-connected Server

In order to control power of a server while connected to the server, the
following conditions must be met:

•

The server must have at least one power cord plugged into an AlterPath
PM that is properly configured and connected to the AUX port.

•

The power outlet(s) that the server is connected to must be configured to
the port.

•

If a regular user is accessing this device, the user must have the following
permissions:

• Full control (read, write, power) permission on the port,

• Permission to control power on the PM outlet that the device is plugged

into.

T

To Power On, Power Off, or Reboot the
Connected Server

1. While connected to a server, use the power management keyboard

shortcut.

The default is Ctrl+k p.

A window similar to the following appears.

2. Select the configured outlet.

3. Do one of the following:

• To turn the power on, select On.

• To turn the power off, select Off.

• To reboot, select Cycle.

To lock or unlock outlets, you must go to the Power Management menu.
See “Power Management” on page 343 for more information.