Lcd status message update – Dell PowerEdge 2970 User Manual

Page 8

Advertising
background image

8

Information Update

LCD Status Message Update

Table 1-1 lists updates to the LCD status messages that can occur and the
probable cause for each message. The LCD messages refer to events recorded
in the system event log (SEL). For information on the SEL and configuring
systems management settings, see your systems management software
documentation.

Table 1-1.

LCD Status Messages

Code

Text

Causes

Corrective Actions

E1232

VDD 12V

PS# PwrGd

AC power was lost on
the specified power
supply while the system
was powered on. If AC
power was not lost, the
specified power supply
has failed.

If AC power was lost, this message
is information only. If the power
supply has failed, see "Getting
Help" in your

Hardware Owner’s

Manual.

E141C

CPU

Mismatch

The existing CPU
pairing in the system is
not supported.

Change the CPUs to a matched
pair or other valid configuration.

Advertising