Lcd status messages update – Dell PowerEdge 1900 User Manual

Page 4

Advertising
background image

4

Information Update

LCD Status Messages Update

Table 1-2 lists updates to the LCD status messages that can occur and the probable cause for each
message. The LCD messages refer to events recorded in the system event log (SEL). For information
on the SEL and configuring system management settings, see your systems management software
documentation.

NOTE:

Each diagnostic LCD message is assigned a priority. The highest priority messages supersede any group

of messages with a lower priority.

Table 1-1.

System Messages

Message

Causes

Corrective Actions

The FBD link to the

following DIMM failed to

train: DIMM

x

FBD training error - The

following memory branch

has been disabled:

Branch

x

An error has occurred on the FBD
channel that contains the specified
DIMM. A fault is indicated on the
link adjacent to the DIMM caused
by a faulty condition in either the
specified DIMM, the next DIMM
in the channel, or possibly the
system board. When this error
occurs, the other FBD branch in the
memory pair is disabled, resulting in
the second error message.

Reseat all of the DIMMs on the
indicated FBD channel. See
"Memory" in the

Hardware Owner’s

Manual for information about the
FBD branches and channels. See
"Troubleshooting System Memory" in
the

Hardware Owner’s Manual. If the

problem persists, see "Getting Help"
in the

Hardware Owner’s Manual.

Table 1-2.

LCD Status Messages

Code

Text

Causes

Corrective Actions

E1118

CPU Temp Interface

The BMC is unable to determine
the CPU(s) temperature status.
Consequently, the BMC increases
the CPU fan speed to maximum
as a precautionary measure.

Turn off power to the system and
restart the system. If the problem
persists, see "Getting Help" in the
Hardware Owner’s Manual.

E122B

0.9 V Over Voltage

0.9 V regulator voltage has exceeded
the allowable voltage range.

See "Getting Help" in the
Hardware Owner’s Manual.

E122C

CPU Power Fault

A voltage regulator failure was
detected when the processor
regulator(s) was enabled.

See "Getting Help" in the
Hardware Owner’s Manual.

Advertising