Page 12 – Louisville Tin and Stove HEDV404 User Manual

Page 12

Advertising
background image

WIRING

This appliance is equipped with a three prong grounding
plug. For your protection against shock hazard, this ap-
pliance should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the ground-
ing prong from this plug.

NOTE: If any of the original wire supplied with this ap-
pliance has to be replaced, it must be replaced with type
105

-C wire or its equivalent.

CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation.

Verify proper operation after servicing.

WARNING

THIS IS A GAS-FIRED APPLIANCE. KEEP THE
AREA CLEAR OF GASOLINE AND OTHER FLAM-
MABLE VAPORS AND LIQUIDS. ALL COMBUS-
TIBLE MATERIAL MUST BE KEPT CLEAR OF THIS
AREA TO AVOID FIRE OR EXPLOSION.

Page 12

Gas Valve

Pressure

Switch

Circulating

Blower

XFMR

L 1

EAC/LSPD

Heat

Hum

M 1

M 2

Black

White

Draft

Inducer

White

White

Neutrals

Flame

Sensor

Brown

White

Black

24 VAC

Transformer

Yellow

Yellow

Thermostat

Yellow
Yellow

White

Red

Black
Black

W

C

R

Y

MODEL HEDV 403, 404

Ignitor

Blue

Blue

High

Limit

Red

Red

Black

White

Green

Thermostat Limit Pressure Gas

Switch Switch Valve

Circulating

Blower

Draft

Inducer

Ignitor

Flame

Sensor

115 VAC

Primary

Transformer

Secondary

24 VAC

3 Amp

Fuse

Advertising