Vent terminal clearances page 4 – Louisville Tin and Stove HEDV404 User Manual

Page 4

Advertising
background image

REFERENCE LETTER TO

DRAWING

CANADIAN

INSTALLATIONS¹

A = Clearance above grade,
veranda, porch, deck, or
balcony

12 Inches (30 cm)

B = Clearance to window or door
that may be opened

12 Inches (30 cm)

C = Clearance to permanently
closed window

12 Inches (30 cm)

D = Vertical clearance to
ventilated soffit located above
the terminal within a horizontal
distance of 2 Feet (61 cm) from
the center line of the terminal

18 Inches (46 cm)

E = Clearance to unventilated
soffit

18 Inches (46 cm)

F = Clearance to outside corner

12 Inches (30 cm)

G = Clearance to inside corner

12 Inches (30 cm)

H = Clearance to each side of
center line extended above
meter/ regulator assembly

3 Feet (91 cm) within a hei
15 Feet (4.5m) above the
meter/regulator assembly

I = Clearance to service regulator
vent outlet

3 Feet (91 cm)

J = Clearance to nonmechanical
air supply inlet to building or the
combustion air inlet to any other
appliance

12 Inches (30 cm)

K = Clearance to a mechanical
air supply inlet

6 Feet (1.83 m)

L = Clearance above paved
sidewalk or paved driveway
located on public property

7 Feet (2.13m) A vent shal
not terminate directly abo
a sidewalk or paved drivew
th t i l

t d b t

t

VENT TERMINAL CLEARANCES

Page 4

Vent Terminal

Air Supply Inlet

Area where terminal is not permitted