Step – Louisville Tin and Stove HEDV404 User Manual

Page 13

Advertising
background image

STEP #

STEP #

1)

Thermostat calls for heat.

8) Continued...

2)

Combustion fan turns on.

return to Step 2. If after 3 attempts

3)

Pressure switch closes.

malfunction still occurs, furnace will

4)

Power to Ignitor.

go into lockout mode for one hour.

5)

Ignitor warm up period.

This one hour mode can be bypassed

6)

Gas flow to burner.

by resetting thermostat.

7)

Burner ignition proven.

9)

Thermostat satisfied.

8)

Circulating blower on.

10)

Gas valve closes.

NOTE: If there is a mal-

11)

Combustion fan off.

function in any of the

12)

Blower off.

above steps, the sequence
will stop at that point and

HEATER NOW IN STAND-BY MODE.

Page 13

SEQUENCE OF OPERATION - HEDV403/4

Lockout

t=10 sec.

IGNITION

PROVED?

YES

t=50 sec.

NO

Blower

On

@t=X

Thermostat

is satisfied

t=x sec.

Burners

Off

t=X+15 sec.

Combust.

Fan Off

Blower

Off

@t=0

THERMOSTAT

CALLS FOR

HEAT

Power to

Combust.

Fan

10 SEC

PURGE

Three

Attempts

Made?

NO

YES

Fan

Proved

YES

NO

Power to

Ignitor

NO

Three

Attempts

Made?

YES

Gas

Flow

10 SEC

PURGE

t=X+120 sec.

t=15 sec.

t=20 sec.