Improving NFS Performance on HPC Clusters with Dell Fluid Cache for DAS

11

I/O cluster details

Table 5.

I/O cluster configuration

CLIENTS

64 PowerEdge M420 blade servers

32 blades in each of two PowerEdge M1000e chassis

CHASSIS CONFIGURATION

Two PowerEdge M1000e chassis, each with 32 blades

Two Mellanox M4001F FDR10 I/O modules per chassis

Two PowerConnect M6220 I/O switch modules per chassis

INFINIBAND FABRIC

For I/O traffic

Each PowerEdge M1000e chassis has two Mellanox M4001

FDR10 I/O module switches.

Each FDR10 I/O module has four uplinks to a rack Mellanox

SX6025 FDR switch for a total of 16 uplinks.

The FDR rack switch has a single FDR link to the NFS server.

ETHERNET FABRIC

For cluster deployment and

management

Each PowerEdge M1000e chassis has two PowerConnect

M6220 Ethernet switch modules.

Each M6220 switch module has one link to a rack

PowerConnect 5224 switch.

There is one link from the rack PowerConnect switch to an

Ethernet interface on the cluster master node.

I/O compute node configuration

CLIENT

PowerEdge M420 blade server

PROCESSORS

Dual Intel(R) Xeon(R) CPU E5-2470 @ 2.30 GHz

MEMORY

48 GB. 6 * 8 GB 1600 MT/s RDIMMs

INTERNAL DISK

1 50GB SATA SSD

INTERNAL RAID CONTROLLER PERC H310 Embedded

CLUSTER ADMINISTRATION

INTERCONNECT

Broadcom NetXtreme II BCM57810

I/O INTERCONNECT

Mellanox ConnectX-3 FDR10 mezzanine card

I/O cluster software and firmware

BIOS

1.3.5

iDRAC

1.23.23 (Build 1)

OPERATING SYSTEM

Red Hat Enterprise Linux (RHEL) 6.2

KERNEL

2.6.32-220.el6.x86_64