Table 1, Nfs server and storage hardware configuration, Figure 2 – Dell POWEREDGE R720XD User Manual

Page 8: Nfs server, Figure 2. table 1

Advertising
background image

Improving NFS Performance on HPC Clusters with Dell Fluid Cache for DAS

8

NFS server

Figure 2.

NFS server and storage hardware configuration

Table 1.

Server configuration

NFS SERVER

PowerEdge R720

PROCESSORS

Dual Intel(R) Xeon(R) CPU E5-2680 @ 2.70 GHz

MEMORY

128 GB. 16 * 8 GB 1600MT/s RDIMMs

INTERNAL DISKS

5 * 300 GB 15 K SAS disks

Two drives configured in RAID-0 for the operating system

with one additional drive as a hot spare

Two drives configured in RAID-1 for swap space

INTERNAL RAID CONTROLLER PERC H710P mini (internal)

EXTERNAL RAID CONTROLLER PERC H810 adapter (slot 7) connected to the storage

enclosures

INTERCONNECT TO CLIENTS

Mellanox ConnectX-3 FDR card (slot 5)

Storage configuration

Storage Enclosure

Four PowerVault MD1200 arrays, daisy chained

Hard Disks

12 * 3 TB 7200 rpm NL SAS drives per storage enclosure

Advertising
This manual is related to the following products: