Using the cmc cli to set the ip address – Dell PowerEdge M805 User Manual

Page 6

Advertising
background image

8 of 16

4424 QuickStart Guide

Publication Number: 53-1000572-01

Bits per second: 9600

Databits: 8

Parity: None

Stop bits: 1

Flow Control: None

For LINUX or UNIX

a. Enter the following at the command prompt:

tip /dev/ttyb -9600

b. When the terminal application stops reporting information, press Enter to display the login prompt.

c. Log in using the default administrative account

Login: admin

Password: password

d. When prompted either change the administrative password, or press Ctrl-C to bypass.

Task 2: Changing the IP address

1. Verify that the SAN I/O Module has completed POST. When POST is complete, the port status and SAN I/O

Module power and status LEDs return to a standard healthy state.

2. Enter the CLI ipAddrSet command.

Follow on-screen instructions and supply the correct information, as shown in the following example.

switch:admin> ipaddrset

Ethernet IP Address [10.77.77.77]:10.32.53.47

Ethernet Subnetmask [255.255.255.0]:255.255.240.0

Fibre Channel IP Addresss [none]:

Fibre Channel Subnetmask [none]:

Gateway IP Address [0.0.0.0]:10.32.48.1

DHCP [Off]:

IP address is being changed...Done.

3. Enter ipAddrShow at the prompt to verify that the address was correctly set.

Using the CMC CLI to set the IP address

Use the following steps to connect modify the SAN I/O Module IP address through the CMC CLI.

1. Establish a Telnet session to the CMC CLI.

2. At the command prompt, type connect switch-x where x is the bay where the SAN I/O Module is installed. For

example, switch-x can be:

Switch-3 for SAN I/O Module installed in bay B1.

Switch-4 for SAN I/O Module installed in bay B2.

Switch-5 for SAN I/O Module installed in bay C1.

Switch-6 for SAN I/O module installed in bay C2.

3. At the login prompt, log in to the SAN I/O Module. The default user name is “admin” and the password is

“password”.