Issue 1:

Description
XWKGY_Intel10G card shows Flex disabled address after racresetcfg of CMC in Network Device
Page and OS.
Resolution
Virtual reseat or Physical reseat of the server.
Versions/Systems Affected
All CMC versions including CMC 2.0 for Dell PowerEdge VRTX and PowerEdge servers with
iDRAC7 or earlier.

Issue 2:

Description
Io-Identity values are displayed partially in the cmc getmacaddress -c all for 8F6NV(Intel).
Resolution
None
Versions/Systems Affected
CMC 2.0 for Dell PowerEdge VRTX and servers with Intel adapetrs Intel(R) 10G 2P X520-k bNDC
and Intel 10GbE/FCoE Dual KR X-520.

Issue 3:

Description
RACADM displays non ISCI MAC addresses after using ISCI filter in “getmacaddress –m server-x –
t iscsi” command.
Resolution
None
Versions/Systems Affected
All CMC versions including CMC 2.0 for Dell PowerEdge VRTX.

Issue 4:

Description
VLAN settings from the leader chassis are not propagating to member chassis.
Resolution
Login to each member chassis CMC GUI and set the VLAN for iDRAC (Server Overview -> Setup
-> VLAN page).
Versions/Systems Affected
All CMC versions including CMC 2.0 for Dell PowerEdge VRTX and PowerEdge servers with
iDRAC7 or earlier.